755nm Alexandrite Laser Hair Removal 1064nm Long Pulse Laser Beauty Machine Cosmetic Laser
Dual Wavelength 980nm & 1470nm Laser Lipolysis Double Chin Removal Beauty Machine
8-inch Screen Zimmer Cooler Machine
8 inch Screen Time Counting Cold Air Skin Cooling Beauty Machine
Double Handle 755 808 1064 Diode Laser Hair Removal
This professional workstation combines high-intensity pulsed light with near-infrared therapy in a single 500W platform. Designed for medical spas, dermatology clinics, and aesthetic centres, the system delivers targeted treatments for vascular lesions, acne, pigmentation, and skin rejuvenation.
Core capabilities:
11 interchangeable optical filters for condition-specific wavelengths
15-inch 4K touchscreen for precise parameter control
Dual working modes (FPL + NIR) for synergistic effects
Maximum energy output of 50J/cm²
Pulse duration up to 10ms for optimal thermal relaxation
|
Parameter |
Specification |
|
Energy Fluence |
50J/cm² (adjustable 10–50J/cm²) |
|
Pulse Duration |
Max 10ms (1–10ms digitally controlled) |
|
Maximum Power |
500W |
|
Working Modes |
FPL (Fluorescent Pulsed Light) + NIR (Near-Infrared) |
|
Light Source |
High-intensity flashlamp with integrated NIR emitter |
|
Beam Uniformity |
±5% energy homogeneity |
Screen size: 15-inch diagonal
Resolution: 4K (3840 × 2160 pixels)
Technology: Capacitive touchscreen with anti-glare coating
Interface features:
*Pre-set protocol library for each filter type
*Real-time energy monitoring and adjustment
*Patient history storage and recall
*Firmware upgradeable via USB-C port
|
Specification |
Detail |
|
Gross Weight |
67kg |
|
Package Size |
54 × 54 × 115 cm |
|
Power Supply |
220V, 50Hz or 110V, 60Hz (selectable at order) |
|
Cooling System |
Integrated air + contact cooling |
|
Handpiece |
Ergonomic design with swivel cable |
|
Filter Name |
Wavelength |
Primary Indication |
Target Depth |
|
VASCULAR |
530–580nm |
Spider veins, telangiectasia, port-wine stains |
Superficial (0.5–1mm) |
|
ACNE |
400–450nm |
Propionibacterium acnes, active inflammatory acne |
Superficial |
|
515nm |
515nm |
Freckles, solar lentigines, epidermal pigmentation |
Superficial |
|
560nm |
560nm |
Diffuse redness, general photorejuvenation |
Mid-dermal |
|
585nm |
585nm |
Rosacea, erythema, cherry angiomas |
Mid-dermal |
|
615nm |
615nm |
Leg veins, deeper vascular lesions |
Deep dermal (2–3mm) |
|
640nm |
640nm |
Hair reduction (Fitzpatrick IV–V) |
Deep dermal |
|
690nm |
690nm |
Permanent hair reduction (all skin types) |
Deep dermal |
|
755nm |
755nm |
Melanin-rich targets, alexandrite-equivalent |
Deep dermal |
|
Round spot |
10mm diameter |
Precision areas (nose, periorbital, chin) |
Variable |
|
Square spot |
12 × 12mm |
Large flat surfaces (cheeks, back, thighs) |
Variable |
Vascular conditions → VASCULAR, 585nm, or 615nm (based on vessel depth)
Pigmentation → 515nm or 560nm for epidermal spots
Active acne → ACNE filter (blue light spectrum)
Hair removal → 640nm, 690nm, or 755nm (skin-type dependent)
Precision work → Round spot adaptor
Large area coverage → Square spot adaptor
Delivers high-energy broad-spectrum pulses
Optimal for photothermolysis of vascular and pigment targets
Pulse stacking capability for resistant lesions
Best used with shorter wavelength filters (515–640nm)
Continuous or pulsed output at 810–950nm
Penetrates up to 5mm into dermal layers
Stimulates fibroblast activity and collagen remodelling
Reduces post-treatment inflammation
Ideal as a soothing finish after FPL treatments
Sequential firing: FPL pulse followed immediately by NIR burst
Synergistic effect – photothermolysis plus biostimulation
Reduces total treatment time by 30–40%
Enhances patient comfort with built-in cooling between pulses
Single device replaces multiple standalone systems
Covers vascular, pigment, acne, hair, and rejuvenation indications
Suitable for Fitzpatrick skin types I–V
4K display enables fine adjustments in 1J/cm² increments
Real-time skin impedance monitoring
Automatic shut-off if handpiece overheats or loses contact
Built-in test spot protocol for individualized dosing
500W power output reduces session time significantly
Pre-set protocols minimise operator error
Large touchscreen simplifies training for new staff
67kg robust construction ensures stability during high-volume use
Flashlamp lifespan: 100,000 pulses
NIR LED array rated for 50,000 hours
User-replaceable filters and consumables
Dual voltage compatibility for international use
Conduct patient consultation and skin type assessment
Select appropriate filter based on condition and Fitzpatrick type
Perform a test spot at 10J/cm² on a discrete area
Wait 10–15 minutes to observe any adverse reaction
Set energy (10–50J/cm²), pulse width (1–10ms), and working mode
Choose Round or Square spot adaptor based on treatment area
Glide handpiece with 10–15% overlap between pulses
Monitor real-time energy readout on 4K display
Apply cooling gel or soothing cream
Document settings and patient response
Schedule follow-up session (typically 3–6 weeks apart)
Clean handpiece window with isopropyl alcohol
*Skin impedance sensor – dynamically adjusts fluence to tissue resistance
*Contact detection – prevents firing when handpiece is not fully seated on skin
*Over-temperature protection – automatic cooling pause if tip exceeds 42°C
*Emergency stop – physical button plus on-screen kill switch
*CE marked – complies with IEC 60601-2-57 for laser/light therapy devices
*Protective eyewear – included for operator and patient
*Remote interlock port – for integration with treatment room safety systems
Q: What is the difference between FPL and NIR modes, and when should I use each?
A: FPL and NIR serve distinct clinical purposes:
FPL (Fluorescent Pulsed Light):
Broad-spectrum output (400–750nm)
Targets melanin and hemoglobin
Used for: pigmentation, vascular lesions, hair reduction
Best with short-wavelength filters (515–640nm)
NIR (Near-Infrared):
Continuous output (810–950nm)
Penetrates 3–5mm into dermis
Used for: collagen stimulation, skin tightening, post-treatment soothing
No epidermal damage – safe for all skin types
Combination mode:
FPL pulse followed immediately by NIR burst
One pass – dual action (photothermolysis + biostimulation)
Reduces treatment time by 30–40%
Q: How do I choose the correct filter for different skin types and conditions?
A: Follow this decision tree:
By condition:
Vascular (rosacea, spider veins) → VASCULAR or 585nm
Pigmentation (freckles, sun spots) → 515nm or 560nm
Active acne → ACNE (400–450nm)
Hair removal → 690nm (Fitzpatrick I–III) or 755nm (Fitzpatrick IV–V)
By skin type (Fitzpatrick):
Type I–III → Shorter wavelengths (515–585nm) – safer, superficial targets
Type IV–V → Longer wavelengths (640–755nm) – deeper penetration, less melanin competition
By area:
Small/curved (nose, chin) → Round spot (10mm)
Large/flat (cheeks, back, thighs) → Square spot (12×12mm)
Always: Perform a test spot at 10J/cm² and observe for 10–15 minutes before full treatment.
|
Item |
Detail |
|
Gross Weight |
67kg |
|
Package Dimensions |
54 × 54 × 115 cm |
|
Voltage Options |
220V, 50Hz (EU/Asia) or 110V, 60Hz (North America) |
|
Included Accessories |
11 filters, Round spot adaptor, Square spot adaptor, power cord, user manual, calibration tool, protective eyewear, spare fuse kit, cleaning swabs, filter carrying case |
This IPL laser & NIR Cell light system integrates 11 filter-based therapies, dual working modes, and a 500W power engine into a single clinical workstation. The 15-inch 4K display simplifies protocol selection, while the 50J/cm² maximum energy and 10ms pulse width provide the flexibility to treat vascular, pigment, acne, and hair conditions across diverse skin types. With CE certification, commercial-grade construction, and a comprehensive safety architecture, this device delivers consistent, evidence-based outcomes for practices seeking to expand their light therapy portfolio.

Whatsapp:8613811714803