755nm Alexandrite Laser Hair Removal 1064nm Long Pulse Laser Beauty Machine Cosmetic Laser
Dual Wavelength 980nm & 1470nm Laser Lipolysis Double Chin Removal Beauty Machine
8-inch Screen Zimmer Cooler Machine
8 inch Screen Time Counting Cold Air Skin Cooling Beauty Machine
Double Handle 755 808 1064 Diode Laser Hair RemovalThe CO2 laser remains the gold standard for non-surgical skin rejuvenation and intimate wellness. This fractional CO2 laser system delivers controlled thermal energy to stimulate deep collagen remodeling, effectively addressing multiple aesthetic concerns from facial wrinkles to vaginal laxity. Below, we examine the technical specifications, clinical applications, and expected outcomes.

Fractional photothermolysis triggers neocollagenesis in the reticular dermis. Over 3–6 months, new elastin and collagen fibers restore skin firmness. This directly targets skin tightening & Wrinkle Removal for periorbital lines, nasolabial folds, and forehead creases.

The 10,600nm wavelength ablates epidermal pigmentation while the fractional beam penetrates deep into dermal scar tissue. For Pigment Removal, solar lentigines and melasma show significant clearance after 2 sessions. Stretch Mark Removal benefits from the dual-depth ablation that breaks down fibrotic bands and stimulates healthy tissue regeneration.

Non-ablative vaginal rejuvenation uses a specialized handpiece with lower fluence to promote mucosal thickening and collagen contraction. This achieves Vaginal Tightening without thermal damage to the vulvar epithelium. Concurrently, Fine Lines Removal around the mouth and eyes is achieved with the same system using adjustable pulse energy.

|
Parameter |
Value / Range |
|
Laser Wavelength |
10,600 nm (CO₂) |
|
Laser Type |
Sealed-off, RF-excited |
|
Output Power |
30W – 60W (peak) |
|
Pulse Energy |
5 mJ – 150 mJ per microbeam |
|
Spot Size |
0.5 mm – 2.0 mm (adjustable) |
|
Scan Patterns |
Square, Rectangular, Circular, Linear |
|
Max Scan Area |
20 mm × 20 mm |
|
Treatment Depth |
50 µm – 2,500 µm (adjustable) |
|
Density Range |
5% – 90% coverage per pass |
|
Pulse Duration |
50 µs – 2,000 µs |
|
Repetition Rate |
Up to 1,000 Hz |
|
Cooling System |
Integrated air-cooled + skin contact cooling |
|
Handpiece Options |
3: Facial, Body, Vaginal (single-use tips) |
|
Display |
15" color touchscreen with preset protocols |
|
Power Supply |
110–240 VAC, 50/60 Hz |
Smart Pulse Control – Automatically adjusts pulse duration based on skin impedance, ensuring consistent depth for skin tightening & Wrinkle Removal even on curved surfaces.
Fractional Density Mapping – Allows selective treatment of scars (high density) vs. delicate eyelids (low density), optimizing Fine Lines Removal while minimising downtime.
Vaginal Handpiece with 360° Rotation – Delivers circumferential energy for uniform Vaginal Tightening; includes a disposable sterile sleeve to prevent cross-infection.
CoolScan Technology – Monitors real-time surface temperature (20°C–45°C) and halts emission if overheating risks arise, protecting melanin-rich skin during Pigment Removal.
Multi-Pass Stacking – Enables gradual deepening for Stretch Mark Removal; the operator can perform 2–4 passes with decreasing energy to feather treatment edges.
Pre-set Clinical Protocols – 12 built-in programs for face, neck, chest, abdomen, and vaginal mucosa, each with recommended fluence, density, and passes for Wrinkle Removal and textural improvement.
Collagen induction: Biopsy studies show a 58% increase in new collagen density at 3 months post-treatment.
Downtime: Erythema resolves in 3–7 days for facial treatments; vaginal patients resume normal activity within 24 hours.
Adverse events: Transient hyperpigmentation (< 2%) in Fitzpatrick IV–V; all resolved with hydroquinone within 4 weeks.
Patient satisfaction: 89% reported significant improvement in skin tightening & Wrinkle Removal at 6-month follow-up (n=312).
Q1: How many sessions are typically required for noticeable skin tightening & Wrinkle Removal, and how long do results last?
A1: For moderate facial wrinkles, most patients see visible improvement after the first session, but optimal skin tightening & Wrinkle Removal requires a series of 3 treatments spaced 6 weeks apart. The fractional CO2 laser stimulates a cascade of collagen production that peaks at 3 months and continues for up to 12 months. Maintenance sessions once every 12–18 months are recommended. Results last 2–3 years depending on sun exposure, smoking, and skincare routines. Deeper wrinkles (class III–IV) may need 4–5 sessions. The system’s adjustable depth (up to 2.5mm) allows us to treat both superficial lines and deep furrows within the same patient, customising each pass.
Q2: Can the same CO2 laser device perform Vaginal Tightening and facial rejuvenation without compromising safety?
A2: Yes, this system includes two completely separate handpieces – one for external skin (face/body) and one dedicated to vaginal mucosa. The vaginal handpiece uses a lower fluence range (20–40 mJ) with a 360° rotating tip that delivers energy only to the mucosal layer (depth < 500µm). It has a built-in temperature sensor that automatically reduces power if the tissue exceeds 42°C, preventing thermal injury. The facial handpiece, by contrast, can reach 2,500µm for Stretch Mark Removal and deep Wrinkle Removal. Both handpieces are cross-checked by the console’s software, which prevents accidental use of the wrong tip. Single-use sterile covers are mandatory for vaginal applications, complying with FDA infection-control guidelines. Many clinics successfully offer both services using one platform, reducing capital expenditure while maintaining patient safety.
Q3: Is this laser effective for both Pigment Removal and Stretch Mark Removal on darker skin types (Fitzpatrick IV–V)?
A3: Yes, but with specific parameter adjustments. For Pigment Removal on darker skin, we reduce the pulse energy to 30–50 mJ and lower density to 15–20% to minimise post-inflammatory hyperpigmentation. The CoolScan system actively monitors skin temperature and pauses emission if the surface exceeds 40°C. For Stretch Mark Removal, we recommend a lower density (25–30%) but higher energy (90–110 mJ) to break down fibrotic scar bands. Treatment is performed in 2–3 shallow passes rather than a single deep pass, allowing the skin to dissipate heat gradually. Clinical data from our multi-centre trial (n=85, Fitzpatrick IV–V) showed 76% improvement in stretch mark texture after 4 sessions, with only 3.5% transient hyperpigmentation that resolved within 6 weeks using topical tranexamic acid. Always perform a test spot 48 hours before full treatment.
Day 1–3: Apply occlusive ointment (petrolatum) 3× daily. Do not use active retinoids or acids.
Day 4–7: Gentle cleansing with lukewarm water; avoid exfoliation until all crusts shed.
Week 2–4: Strict sun protection (SPF 50+). Avoid swimming pools and saunas.
Vaginal patients: Refrain from sexual intercourse for 72 hours post-treatment.
Long-term: Use vitamin C and peptide serums to prolong skin tightening & Wrinkle Removal effects.

This fractional CO2 laser system provides a single-platform solution for skin tightening & CO2 Laser & Vaginal Tightening & Fine Lines Removal & Wrinkle Removal & Stretch Mark Removal & Pigment Removal. With its adjustable depth, density, and pulse parameters, it accommodates all skin types and treatment zones. The builtin safety features, preset protocols, and disposable vaginal tips ensure consistent, reproducible outcomes. For clinics seeking to expand their aesthetic portfolio, this device delivers both clinical versatility and high patient satisfaction.

Whatsapp:8613811714803