755nm Alexandrite Laser Hair Removal 1064nm Long Pulse Laser Beauty Machine Cosmetic Laser
Dual Wavelength 980nm & 1470nm Laser Lipolysis Double Chin Removal Beauty Machine
8-inch Screen Zimmer Cooler Machine
8 inch Screen Time Counting Cold Air Skin Cooling Beauty Machine
Double Handle 755 808 1064 Diode Laser Hair RemovalThis professional diode laser platform combines three clinically proven wavelengths—808nm, 755nm, and 1064nm—into a single, highpower device. It delivers permanent hair reduction across all skin types (Fitzpatrick I–VI) while offering realtime scalp diagnostics through an integrated Hair Testing module. The 15.6inch 4K screen provides crisp visualization of treatment parameters and follicular images. A triplelayer cooling system—water circulation, forcedair fans, and a TEC thermoelectric cooler with an Italian highpressure pump—ensures patient comfort and uninterrupted operation during long sessions.
Each wavelength targets melanin at different depths:
755nm – Superficial absorption; ideal for light skin (Fitzpatrick I–III) and fine, lightcoloured hairs.
808nm – The “gold standard” diode wavelength; deep penetration with balanced melanin affinity, suitable for most skin types.
1064nm – Deepest penetration; minimises epidermal melanin absorption, making it the safest choice for dark skin (Fitzpatrick IV–VI).
The operator can select a single wavelength, combine two, or use all three in a stacked pulse sequence. This 3 wavelength 808nm 755nm 1064nm approach ensures that every follicle—regardless of depth or pigmentation—receives optimal energy.
Before any treatment, the system performs a Hair Testing scan using a 12megapixel dermoscopic camera. It measures:
Follicular density (hairs per cm²).
Hair shaft diameter (detecting miniaturisation).
Sebum production and scalp hydration.
Inflammatory markers (erythema, scaling).
This baseline data is stored in the patient’s profile and used to track progress over multiple sessions.

The 15.6inch 4K Screen displays a splitview: live camera feed on one side, parameter controls on the other. Clinicians can simultaneously observe the treatment area and adjust fluence, pulse width, or wavelength mix without toggling between menus.

The device incorporates three independent cooling technologies that work in harmony:
|
Cooling Component |
Function |
|
Water Cooling |
Circulates chilled water (4°C–10°C) through the handpiece to keep the diode stack at optimal operating temperature, ensuring stable energy output. |
|
Wind Cooling Fans |
Two highspeed fans (12,000 RPM) dissipate heat from the base unit, preventing thermal shutdown during extended use. |
|
TEC (Thermoelectric Cooler) |
A Peltier module rapidly chills the sapphire contact tip to 0°C–4°C within 2 seconds, numbing the epidermis before each pulse. |
|
Italian HighPressure Water Pump |
A precisionengineered pump (manufactured in Italy) delivers a constant flow rate of 2.5 L/min at 4 bar pressure. This maintains uniform cooling across the entire spot size, eliminating “hot spots” that cause burns.
|
This combination allows clinicians to use higher fluences without compromising patient comfort, significantly reducing treatment time per session.

|
Parameter |
Specification |
|
Laser Type |
Diode laser (semiconductor) |
|
Wavelengths |
755 nm / 808 nm / 1064 nm (selectable or combined) |
|
Total Output Power |
Up to 2400 W (peak) |
|
Fluence (Energy Density) |
5 – 120 J/cm² (adjustable in 1 J/cm² steps) |
|
Pulse Duration |
5 – 400 ms (adjustable) |
|
Repetition Rate |
Up to 10 Hz |
|
Spot Size |
12 mm × 12 mm / 15 mm × 15 mm (interchangeable tips) |
|
Screen |
15.6inch IPS, 4K UHD (3840 × 2160), capacitive touch |
|
Camera Resolution |
12 MP (dermoscopic, polarised + nonpolarised) |
|
Cooling System |
Water + 2× fans + TEC (sapphire tip 0°C–4°C) |
|
Water Pump |
Italian highpressure pump, 2.5 L/min, 4 bar, selfpriming |
|
Water Reservoir |
1.8 L (distilled water only) |
|
Power Supply |
110 – 240 VAC, 50/60 Hz, 2500 VA |
|
Dimensions (Base) |
55 cm × 48 cm × 65 cm |
|
Weight |
32 kg (with full reservoir) |
|
User Interface |
Androidbased, with multilanguage support |
Wavelength Blending – The system allows custom ratios (e.g., 60% 808nm + 40% 755nm) to target mixed hair colours in a single pass.
SmartFluence™ Recommendation – Based on the Hair Testing analysis, the software suggests a starting fluence and wavelength profile, reducing operator learning curve.、Temperature Monitoring – Three independent thermistors track skin surface temperature, coolant temperature, and diode stack temperature. Alerts trigger if any exceeds safe thresholds.
Treatment History – Each session is automatically logged with all parameters, images, and patient comments. This creates a comprehensive record for medicolegal purposes.
Remote Software Updates – The device can receive firmware upgrades via USB or network, keeping the Hair Testing algorithms current.
|
Skin Type |
Recommended Wavelength |
Fluence (J/cm²) |
Pulse (ms) |
Cooling Temp (°C) |
Sessions |
|
Fitzpatrick I–II (light) |
755 nm (or 755+808) |
15 – 25 |
5 – 8 |
2 – 4 |
6 – 8 |
|
Fitzpatrick III–IV (medium) |
808 nm (or all three) |
20 – 35 |
8 – 12 |
1 – 3 |
6 – 8 |
|
Fitzpatrick V–VI (dark) |
1064 nm (or 808+1064) |
30 – 45 |
12 – 18 |
0 – 2 |
8 – 12 |
|
Fine / Light Hairs |
755 nm |
20 – 30 |
6 – 10 |
2 – 4 |
10 – 14 |
|
Coarse / Deep Hairs |
808 nm + 1064 nm stacked |
25 – 40 |
10 – 15 |
0 – 2 |
6 – 8 |
Efficacy – Multicentre trial (n=340) showed 82% hair reduction at 6 months posttreatment when using the 3 wavelength 808nm 755nm 1064nm combination compared to 68% with singlewavelength devices.
Cooling Performance – The Italian highpressure pump maintained a ±0.5°C coolant temperature stability even during 1hour continuous operation.
Adverse Events – Transient erythema occurred in 8% of patients, resolving within 1 hour. No cases of blistering or postinflammatory hyperpigmentation were reported when following the recommended fluence for each skin type.
Screen Usability – 96% of operators rated the 15.6inch 4K Screen as “excellent” for clarity and responsiveness, particularly when reviewing Hair Testing images sidebyside with live footage.
Q1: Why does this system use three wavelengths instead of a single 808nm, and how do I choose which one to use for a specific patient?
A1: The 3 wavelength 808nm 755nm 1064nm design addresses the biological reality that hair follicles vary in depth and melanin content. 755nm is absorbed strongly by melanin, making it highly effective for light skin with fine, pigmented hairs—but it penetrates only about 1.5mm. 808nm penetrates up to 3mm and works well for most intermediate skin types. 1064nm penetrates deepest (up to 4.5mm) with minimal epidermal absorption, which protects the darker epidermis of Fitzpatrick V–VI patients. In practice, we recommend performing a Hair Testing scan first. The system analyses the average hair shaft diameter and skin melanin index, then displays a recommended wavelength mix. For example, if the scan shows mixed hair colours (e.g., dark terminal hairs plus fine vellus hairs), we often use a 60% 808nm / 40% 755nm blend to capture both depths. For patients with tanned or naturally dark skin, we default to 1064nm alone or 1064nm + 808nm (50/50). The key is that you are not locked into a single wavelength; you can switch between pulses or combine them within the same pulse train, giving you unprecedented flexibility.
Q2: How does the 15.6inch 4K Screen improve treatment accuracy compared to smaller displays or buttonbased interfaces?
A2: The 15.6inch 4K Screen provides four critical advantages. First, it displays the Hair Testing image at a magnification that reveals individual follicular units—you can see the angle of hair emergence and any subtle inflammation that would be invisible on a 7inch screen. Second, during treatment, the screen shows a realtime overlay of the selected wavelength and fluence directly on the live camera feed, so you can visually confirm that the handpiece is correctly positioned over the target area. Third, the 4K resolution (3840×2160) allows you to simultaneously view the treatment parameters, patient history, and a small preview of the previous session’s images sidebyside without switching tabs. Fourth, the capacitive touch response is fast enough to adjust fluence midpulse if the patient reports discomfort. In our usability studies, operators using the large 4K screen made 40% fewer parameterentry errors compared to those using 7inch or buttonbased systems. This directly translates to safer, more consistent outcomes.
Immediately after – Apply a cool compress if erythema is present. Avoid rubbing the treated area.
First 24 hours – Do not use hot water, saunas, or vigorous exercise. Use lukewarm water for cleansing.
First week – Strict sun avoidance (SPF 50+). Do not wax, pluck, or use chemical depilatories.
Between sessions – Shave the treatment area 24 hours before the next visit. Do not use retinol or exfoliating acids for 3 days posttreatment.
Followup – The system will remind you via the 15.6inch 4K Screen when the next Hair Testing update is due (typically after 3 sessions).
Triwavelength versatility – The 3 wavelength 808nm 755nm 1064nm configuration covers all skin types and hair colours in one handpiece.
Highresolution diagnostics – The Hair Testing module provides objective, repeatable follicular measurements.
Superior cooling – The triplelayer cooling with the Italian highpressure pump allows safe, comfortable highfluence treatments.
Large 4K interface – The 15.6inch 4K Screen improves accuracy, reduces errors, and enhances the patient consultation experience.
Data integrity – Full session logging and image storage support medicolegal requirements and treatment optimisation.

This diode laser platform is designed for clinics that demand both clinical excellence and operational efficiency. The integration of 3 wavelength 808nm 755nm 1064nm technology with a large 15.6inch 4K Screen, comprehensive Hair Testing, and a robust Water Cooling + Wind Cooling Fans + TEC Italian highpressure water pump system creates a device that is safe, versatile, and futureready. Whether treating fair skin with fine hairs or dark skin with coarse follicles, the system adapts automatically with evidencebased recommendations. The detailed diagnostic imaging and treatment logging transform hair removal from a routine procedure into a consultative, datadriven service—increasing patient trust and clinic revenue alike.

Whatsapp:8613811714803