The OW-G2 is a professional-grade CO2 laser system engineered for aesthetic clinics and dermatology practices. With its 10,600nm wavelength and adjustable power output from 1 to 60W, this device delivers controlled thermal ablation for effective skin resurfacing, fine lines removal, and deep dermal remodeling. Whether you target periorbital wrinkles, acne scars, or pigmented lesions, the OW-G2 offers versatile scan modes and a compact articulated arm for precise, hands-on treatment.
|
Parameter |
Detail |
|
Model Number |
OW-G2 |
|
Laser Type |
CO₂ Laser (10,600nm) |
|
Machine Power |
1–60W (adjustable) |
|
Graphic Area |
≤ 20mm × 20mm |
|
Focal Spot Diameter |
0.25mm |
|
Focal Spot Area |
0.05mm² |
|
Pulse Modes |
CW, Pulse, Single Pulse, Super Pulse |
|
Target Wavelength |
635nm (aiming beam) |
|
Target Optical Power |
≤ 5mW |
|
Optical System |
7-Joint Articulated Arm |
|
Refrigeration |
Air-cooled or Air + Water |
|
Operating Voltage |
AC 220V ±10%, 50Hz |
|
Package Size (Main) |
55×45×125cm |
|
Arm Package Size |
105×35×20cm |
|
Net Weight |
70kg |
Deep wrinkle correction – CW and Pulse modes allow continuous or chopped energy delivery for deeper dermal heating, stimulating neocollagenesis.
Fullface resurfacing – The 20×20mm graphic area covers large zones efficiently, while the 0.25mm spot size ensures highresolution treatment.
H3: Advanced Scan Modes for Tailored Outcomes
The OWG2 features three distinct scan strategies, each optimised for different tissue responses:
|
Scan Mode |
Pattern |
Best For |
|
Surface Mode |
Spiral shape |
Even ablation of superficial epidermis – ideal for skin resurfacing and fine texture improvement. |
|
Deep Mode |
Random, Sequential, or Midsplit |
Fractional deep dermal coagulation – targets wrinkle removal and atrophic scars with controlled penetration. |
|
Blend Mode |
Spiral + Random / Sequential / Midsplit |
Combines superficial ablation with deep coagulation – maximum effect for fine lines removal and laxity. |
Standard shapes: Triangle, Rectangle, Circle, Hexagon (independently adjustable X/Y dimensions).
Custom shape upload – treat non uniform lesions or follow anatomical contours with ease.
Four pulse modes:
CW – constant energy for rapid ablation.
Pulse – repetitive on/off cycles to reduce thermal damage.
Single Pulse – precise spot firing for small lesions.
Super Pulse – high-peak-power, short-duration pulses for skin resurfacing with faster re-epithelialisation.
H3: Optical and Cooling Systems
635nm aiming beam (<5mW) provides clear visual guidance, ensuring accurate placement over wrinkles or scars.
Dual cooling options – air-cooled for portable setups, or air+water for extended sessions (reduces thermal drift and maintains stable output).
H3: Physical Footprint and Installation
Main unit: 55×45×125cm; arm package: 105×35×20cm.
Total weight 70kg – robust yet movable with casters (not shown, but standard on similar units).
Operates on standard 220V ±10%, 50Hz – compatible with most clinic power infrastructures.
The OWG2 is not limited to facial rejuvenation. Its fractional and ablative capabilities address multiple indications:
Acne scar treatment – Deep Mode with sequential scan creates microscopic columns of coagulation, triggering remodelling of fibrotic tissue.
Pigmentation removal – Superficial ablation in Surface Mode exfoliates epidermal melanin, while the 10,600nm wavelength is absorbed by water, not melanin, reducing unwanted pigment interaction.
Stretch mark reduction – Blend Mode combines spiral ablation with random deep coagulation, breaking down striae bands and stimulating new collagen alignment.
Actinic keratosis and benign lesions – Single Pulse mode allows precise vaporisation with minimal surrounding damage.
Q: Can the OW-G2 effectively treat stretch marks, pigmentation, and acne scars in one session?
A: While one session can show improvement, optimal results typically require 2–4 sessions spaced 4–6 weeks apart. The OW-G2’s Blend Mode is specifically designed for mixed indications: the spiral component resurfaces pigmented epidermis, while the random or midsplit deep columns target the dermal fibrosis underlying stretch marks and atrophic acne scars. Power settings (30–50W) and scan density are adjusted per indication – lighter for pigmentation, higher for scars. Unlike many fractional devices that use fixed spot sizes, the OW-G2’s 0.25mm spot and variable scan patterns give you granular control over ablation depth and coagulation zone, making it suitable for both Fitzpatrick II and IV skin types when proper cooling and energy titration are applied.
Q: What posttreatment care is required after using the OWG2 for acne scar and pigmentation removal?
A: Immediately posttreatment, the skin appears erythematous and may have pinpoint bleeding or exudate – this is normal. We recommend occlusive ointment (e.g., petrolatum) for the first 48 hours, followed by gentle cleansing and a broad-spectrum sunscreen (SPF 50+) for at least 6 weeks. Avoid direct sun exposure and exfoliating agents (retinoids, AHAs) for 7–10 days. The epidermal renewal cycle completes in 5–7 days for superficial settings, but deeper scar treatments may require 10–14 days of crusting. Patients should expect temporary hyperpigmentation in darker skin types, which resolves with consistent sun protection. We always perform a test spot 2 weeks prior to full treatment for high-risk individuals.
Q: How does the Deep Mode (Random, Sequential, Midsplit) improve outcomes for stretch mark and scar revision compared to standard spiral scanning?
A: Standard spiral scanning (Surface Mode) only treats the epidermis and papillary dermis – insufficient for stretch marks or deep boxcar scars. Deep Mode uses a fractional approach: it creates isolated micro-thermal zones (MTZs) that extend into the reticular dermis. The Random pattern prevents thermal stacking, reducing bulk heating and pain. Sequential delivers lines of coagulation in a grid, ideal for linear striae. Midsplit divides the treatment area into two passes with overlapping edges, ensuring complete coverage without gaps. By sparing the surrounding tissue, these modes accelerate healing while achieving up to 40% dermal collagen contraction. For stretch marks, we recommend 40–50W, Midsplit, with a 20% density; for acne scars, Sequential at 30–40W with 15% density. The OWG2’s 60W ceiling gives you the headroom to treat even resistant scarring without underdosing.
Fast setup – The articulated arm locks into position; the control panel (not shown) offers preset parameters for common indications.
Costeffective – Consumables are limited to the aiming beam battery (if applicable) and occasional lens cleaning – no expensive disposable tips.
Safety – Builtin interlock and footswitch (standard) ensure operator control; the 635nm aiming beam is Class 2, safe for routine use.
The OW-G2 CO2 laser stands as a reliable workhorse for practitioners seeking a single device for wrinkle removal, skin resurfacing, fine lines removal, and deeper textural issues like scars and pigmentation. Its three scan modes, adjustable power, and customisable output shapes provide the versatility needed for individualised treatment plans. Backed by solid technical specifications – from the 7-joint arm to the dual cooling system – this unit delivers consistent, reproducible clinical outcomes. For clinics expanding their aesthetic portfolio, the OW-G2 offers a balance of performance, safety, and value that meets the demands of modern dermatology.